Installation Instructions
3.0 Unit Installation
Profile
NOTE: Handle the fan/venturi assembly with care, as the fan
blade is not protected by the venturi once removed.
3.3.3. Store the fan / venturi assembly in a
safe area until final installation to
ensure no damage. Store the fan
upside down (on the motor) ensuring
no damage to the fan assembly. (Do
not store in the gutter.)
NOTE: Warranty claims for damaged motors, impellers or venturis will
not be recognised if the motor / venturi has been damaged during
installation.
3.3.4. Lift unit chassis onto the roof. When locating the unit onto the dropper duct,
ensure the water reservoir is on the low roof side of the dropper duct.
3.3.5. Fit the unit level on the dropper duct to ensure even water distribution.
3.3.6. Check the unit is located correctly on the dropper duct. Locate the unit on the
correct chassis duct location points for the appropriate dropper duct size. The
unit should be central on the dropper duct.
3.3.7. Fix the unit into position with self-tapping type screws by screwing through the
unit duct adaptor flange and into the dropper duct. A minimum of 4 screws
should be used on each accessible side of the unit.
Page 9